中文

  • Home
  • About UsOverview | Mission & Vision | Our Customers | Business Partners | Approvals & Certifications | Milestones
  • ProductsProduct Categories | Business Solutions | Addison & Your Business | Ordering & Testing Information | Warranty
  • Download Product Catalogue | Online Document Viewing
  • Technical Lib Cable Related Standards | Cable Testing & Fire Resistant Cable | Cabling System Library | Material Properties | Cable Glossary
  • Contact
  • Enquiry
  • Sitemap
  • Links Testing Authorities | Testing Equipment Manufacturers | Cable Magazines | Cable Organizations | Addison Corporater Website
  • Airport Cables
  • Alarm & Audio Cables
  • Aluminium Conductor Cables
  • Automotive Cables
  • Belden Equivalent Cables
  • Bus Cables
  • BS standard Cables
    • BS 5308
    • BS 5467
    • BS 6346
    • BS 6724
    • BS 7211
    • BS 8573
  • Coaxial Cables
  • Cable Glands
  • Cables for Oil Industry
  • Control Cables
  • Composite Cables
  • Data Cable
  • Elevator Cables
  • Fiber Optic Cables
  • Fire Resisting Cables
    • Fire Resisting Cable
    • LSZH Flame Retardant Cable
    • PVC Flame Retardant Cable
  • Flexible Cables
  • Heat Detection Cables
  • High Temperature Cables
  • Highway Cables
  • IEC 60502-1
  • Industrial Cables
    • American (UL) Standard
    • Australian Standard (LV)
    • Australian Standard (MV)
    • British Standard
    • French Standard
    • German Standard
    • Harmonized Code
    • Itanlian Standard
    • JIS Standard
    • Spanish Standard
    • Portuguese Standard
  • Instrumentation Cables
  • Lan Cables
  • Offshore Cables
    • NEK606
    • BS6883 & BS7917
    • UKOOA
    • IEC60092
    • JIS
    • Marine & Gas Cables
  • Power Cables
    • Low Voltage Cables
    • Medium Voltage Cables
    • High Voltage Cables
  • Military Cables
  • Mining Cables
  • Motor Connecting Cables
  • Photovoltaic Cables
  • Railway Cables
  • Rolling Stock Cables
  • Robotics
  • Rubber & Crane Cables
  • Security Cables
  • Special Cables
  • Spiral Cables
  • Telephone Cables
  • Thermocouple Cables
  • Windmill Cables
  Fire resisting Cable  
Fire Retardant Power & Control Cables
Fire Retardant Instrumention Cables
Fire Retardant RS485 Databus Cables
Fire Retardant Data Cables
Fire Retardant Coaxial Cables
Fire Retardant Fiber Optic Cables

600/1000V XLPE Insulated, LSZH Sheathed, Double steel tape armoured Power Cables (2 Cores) 

FTX400 1RZ1MZ1-R (CU/XLPE/LSZH/DSTA/LSZH 600/1000V Class 2)

APPLICATION 

The cables are mainly used in power stations, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals, and high-rise buildings.

STANDARDS

Basic design adapted to IEC 60502 -1

FIRE PERFORMANCE

Flame Retardance (Single Vertical Wire Test)

EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); 

CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*

Reduced Fire Propagation   (Vertically-mounted bundled wires & cable test)

EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4

Halogen Free

IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; 

CEI 20-37/2-1 ; BS 6425-1*

No Corrosive Gas Emission

IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; 

CEI 20-37/2-2 ; BS 6425-2*

Minimum Smoke Emission

IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; 

CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*

No Toxic gases

NES 02-713; NF C 20-454

Note: Asterisk * denotes superseded standard.

VOLTAGE RATING

600/1000V

CABLE CONSTRUCTION

Conductor: Plain annealed copper wire, normal stranded or compact stranded according to IEC 60228 class 2.

Insulation: Extruded cross-linked XLPE compound. 

Inner Sheath: LSZH compound.

Armouring: Double steel tape  

Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option.

COLOUR CODE

Insulation Colour as per BS7671

With Earth Conductor

Without Earth Conductor

2Cores

-

Brown, Blue

3Cores

Yellow/Green, Brown, Blue

Brown, Gray, Black

4Cores

Yellow/Green, Brown, Gray, Black

Brown, Gray, Black, Blue

5Cores

Yellow/Green, Brown, Gray, Black, Blue

Brown, Gray, Black, Blue, Black

Above 5 Cores

Yellow/Green, Black Numbered

Black Numbered

Sheath Colour: Black (other colors upon request)

Physical AND THERMAL PROPERTIES

Temperature Range During Operation: -30°C – +90°C
Temperature Range During Installation: -5°C – +50°C

Minimum Bending Radius: 10 x Overall Diameter

Electrical PROPERTIES

Dielectric test:

3500 V r.m.s. x 5’ (core/core);

Insulation resistance

≥1000 MΩ x km (at 20°C)

Short circuit temperature  

250°C

CONSTRUCTION PARAMETERS

Conductor

FTX400 1RZ1MZ1-R

No. of Core X

Cross Section

No./Nominal

Diameter of

Strands

Diameter

Overall 

Conducrtor

Nominal

Insulation

Thickness

Steel 

Tape 

Thickness

 Nominal

Sheath

Thickness

Nominal

Overall 

Diatemer

Max.DC resistance of conductor @20°C

Approx.Weight

mm2

No/mm

mm

mm

mm

mm

mm

Ω/km

Kg/km

2x6

7/1.04

2.90

0.7

0.2

1.8

16.8

3.08

417

2x10

7/1.35

3.75

0.7

0.2

1.8

18.5

1.83

539

2x16

7/1.70

4.75

0.7

0.2

1.8

20.5

1.15

704

2x25

7/2.14

5.85

0.9

0.2

1.8

23.5

0.727

971

2x35

7/2.52

6.90

0.9

0.2

1.8

25.6

0.524

1,216

2x50

19/1.78

8.15

1.0

0.2

1.8

28.5

0.387

1,582

2x70

19/2.14

9.75

1.1

0.2

1.9

32.3

0.268

2081

2x95

19/2.52

11.45

1.1

0.2

2.0

36.4

0.193

2749

2x120

37/2.03

12.85

1.2

0.5

2.2

41.1

0.153

3,727

2x150

37/2.25

14.30

1.4

0.5

2.3

45.1

0.124

4,509

2x185

37/2.52

15.95

1.6

0.5

2.5

49.9

0.0991

5,523

2x240

61/2.25

18.25

1.7

0.5

2.6

55.3

0.0754

6981

2x300

61/2.52

20.40

1.8

0.5

2.8

60.7

0.0601

8,383

2x400

61/2.85

23.35

2.0

0.5

3.0

67.9

0.0470

10,897

Electrical PROPERTIES

Conductor Operating Temperature : 90°C

Ambient Temperature : 30°C


Current-Carrying Capacities (Amp)

Conductor
cross-sectional
area

 

Reference Method 1 

(clipped
direct)

Reference Method 11

 (on a perforated 

horizontal cable trayor 

Reference Method 13 [free air] )

In single-way ducts

Laid direct in ground

one 2-core cable single

 phase a.c. or d.c.

one 3-core or 4-core cable 3-phase a.c.

one 2-core cable 

single phase a.c. or d.c.

one 3-core or 4-core cable 3-phase a.c.

one 2-core cable single

 phase a.c. or d.c.

one 3-core or 4-core cable 3-phase a.c.

one 2-core cable single 

phase a.c. or d.c.

one 3-core or 4-core cable 3-phase a.c.

1

2

3

4

5

6

7

8

9

mm2

A

A

A

A

A

A

A

A

6 

62

53

66

56

-

50

-

60

10 

85

73

90

78

-

65

-

80

16 

110

94

115

99

115

94

140

115

25 

146

124

152

131

145

125

180

150

35 

180

154

188

162

175

150

215

180

50 

219

187

228

197

210

175

255

215

70 

279

238

291

251

260

215

315

265

95 

338

289

354

304

310

260

380

315

120 

392

335

410

353 

355

300

430

360

150 

451

386

472

406

400

335

480

405

185 

515 

441

539

463 

455

380

540

460

240 

607

520

636

546

520

440 

630

530

300 

698

599

732

628

590

495 

700

590

400 

787

673

847

728

660

560

790 

670

Voltage Drop (Per Amp Per Meter)

Conductor 
cross-sectional area

2-core cable d.c.

2 cables, single-phase a.c.

3 or 4 cables, 3-phase a.c.

2 cables,
single-phase
a.c.

3 or 4 cables,
3-phase a.c.

In ducts or
in ground

In ducts or
in ground

1

2

3

4

5

6

mm2

mV/A/m

mV/A/m

mV/A/m

mV/A/m

mV/A/m

6 

7.9

7.9

6.8

7.9

6.5

10 

4.7 

4.7

4.0

4.7

3.9

16 

2.9

2.9

2.5

2.9

2.6

 

 

r

x

z

r

x

z

 

 

25 

1.850

1.350

0.160

1.900

1.600

0.140

1.650

1.900

1.600

35 

1.350

1.350

0.155 

1.350

1.150

0.135

1.150

1.350

1.200

50 

0.980 

0.990 

0.155 

1.000 

0.860 

0.135 

0.870

1.000 

0.870

70

0.670 

0.670 

0.150 

0.690 

0.590 

0.130 

0.600 

0.690

0.610

95 

0.490 

0.500 

0.150 

0.520 

0.430 

0.130 

0.450 

0.520 

0.450

120 

0.390 

0.400 

0.145

0.420 

0.340 

0.130 

0.370 

0.420 

0.360

150 

0.310

0.320

0.145 

0.350 

0.280 

0.125

0.300

0.350 

0.300

185 

0.250 

0.260 

0.145 

0.290 

0.220 

0.125

0.260 

0.290

0.250

240 

0.195 

0.200 

0.140 

0.240 

0.175 

0.125

0.210 

0.240 

0.210

300 

0.155 

0.160 

0.140 

0.210 

0.140 

0.120

0.185 

0.210 

0.190

400 

0.120 

0.130 

0.140 

0.190 

0.115 

0.120

0.165 

0.190

0.180

Note : 

r = conductor resistance at operating temperature
x = reactance
z = impedance

 

 

E-mail: uk@addison-cables.com

 

Addison

Marchants Industrial Centre, Mill Lane Laughton, 
Lewes, East Sussex, BN8 6AJ, UK

Tel: 44-207-4195087

Fax: 44-207-8319489

Email: sales@addison-cables.com